The PSB Switch is a direct mount switch for critical pressure points. It has one limit contact that can be used to activate an alarm, actuate indicator lights or shutdown equipment. A glass-filled nylon terminal block with quick screw terminal connections gives the PSB switch a real advantage in industrial engine applications in general purpose non-classified areas. The PSB is ideal when a reading is not desired, but pressure is critical to operational efficiency.
PSB-75-F15: Direct Mount Pressure Switch
The PSB-75-F15 is a direct mount switch for critical pressure points. It has one limit contact that can be used to activate an alarm, actuate indicator lights or shutdown equipment. The trip point on this model is factory preset at 15 psi Falling, with a range of 0-75 psi.
Price:
PSB-100-F20: Direct Mount Pressure Switch
The PSB-100-F20 is a direct mount switch for critical pressure points. It has one limit contact that can be used to activate an alarm, actuate indicator lights or shutdown equipment. The trip point on this model is factory preset at 20 psi Falling, with a range of 0-100 psi.
Price:
Model PSB Direct Mount Pressure Switch
■ Limit Switch for Critical Pressure
■ Operate Alarms or Shutdown Equipment
■ SPDT Snap-Acting Switch
■ Fits Most Engine Applications
Description
The PSB switch is a direct mount switch for critical pressure points. It has one limit
contact that can be used to activate an alarm, actuate indicator lights or shutdown
equipment. The construction of this instrument is the same as our time-proven Swichgage.
instrument. A precision machined brass mounting plate and port captures a high
quality stamped beryllium copper diaphragm. The single-pole, double-throw
(SPDT) snap-switch is operated directly from the diaphragm for quick acting and
positive switching. Trip point is factory preset according to your specifications.
Housing is weather sealed to prevent entry of moisture, dust, etc. A glass-filled nylon
terminal block with quick screw terminal connections gives the PSB switch a real
advantage in industrial engine applications. The PSB is ideal when reading is not desired,
but pressure is critical to operational efficiency.
Intended for use in general purpose nonclassified areas.
Applications
. Engine Lubrication . Water pumps
. Compressors . Oil field systems
. Irrigation systems
. Construction Equipment
. Mobile Equipment
. Marine engines . Generators
Features
. Fits all engine applications
. SPDT snap-switch
. Activates indicator lights, alarms, or shut
down equipment
. Time-proven SWICHGAGE. construction
. Easy wiring terminal block
. Steel housing specially coated to resist
corrosion
. Factory preset to your specifications
Specifications
Housing: Plated steel.
Pressure Connection: 1/8-27 NPT, Brass.
Diaphragm: Formed beryllium copper (heat
treated).
Pulsation Dampener: Brass (it is removable
for cleaning).
Terminal Block: Three #4-40 screws.
Accuracy: Trip point: ±3% of full scale.
Switch reset differential: ±7% of full scale.
Repeatability: ±1% of full scale.
Contact Rating: SPDT 3 A @ 30 VDC
inductive.
Maximum Pressure: See Trip Point Chart
on reverse side.
Temperature Range:
Ambient= -40°F (-40°C) thru 150°F (66°C).
Process= -40°F (-40°C) thru 250°F (121°C).
Factory Trip Point Setting: See Trip Point
Chart (on back).
Pressure Range: Specify from 0-400 psi (0
2.76 MPa) [0- 27.58 bar]. See Trip Point
Chart on reverse side.
Contact: Operates on rising or falling
pressure (specify).
Shipping Weight: 8 oz. (0.25 kgs).
Shipping Dimensions: 3 x 2-3/4 x 2-3/4 in.
(76 x 70 x 70 mm).
NOTE: No customer replacement parts.
**Products covered by this bulletin comply with EMC Council directive 89/336/EEC
regarding electromagnetic compatibility except as noted.
PSB-9104B page 1 of 2
2-1/4 in.
(57 mm)
NO C NC
2-9/16 in.
(65 mm)
1/2 in. (13 mm)
Square wrench flats
1/8-27 NPT
2-1/32 in. Dia.
(52 mm)
Slot head terminal
screws (4-40, UNC-2A)
Dimensions Installation Instructions
Mounting
CAUTION: Use wrench on shank to tighten or loosen pressure
connection. DO NOT TWIST CASE, which will damage the unit and
void the warranty.
1. Before installing the PSB switch, apply sealant, such as Teflon tape,
to the threads (be sure sealant does not block the inlet orifice).
2. The PSB can be mounted in horizontal or vertical angles (do not
mount switch facing down).
3. Locate the unit in place and secure it by tightening
the 1/8-27 NPT fitting into the desired location (do not
overtighten). DO NOT TWIST CASE.
Trip Point Chart
Ranges available Factory setting* Maximum pressure
psi (kPa/MPa) [bar] psi (kPa) [bar] Falling psi (kPa) [bar]
0-15 (0-103) [0-1.03] 3 (21) [.21] 30 (207) [2.07]
0-30 (0-207) [0-2.07] 7 (48) [.48] 60 (414) [4.14]
0-50 (0-345) [0-3.45] 10 (69) [.69] 100 (0-689) [0-6.89]
0-75 (0-517) [0-5.17] 15 (103) [1.03] 150 (0-1.03) [0-10.34]
0-100 (0-689) [0-6.89] 20 (138) [1.38] 200 (0-1.38) [0-13.79]
0-150 (0-1.03) [0-10.34] 30 (207) [2.07] 300 (0-2.07) [0-20.70]
0-200 (0-1.38) [0-13.79] 50 (345) [3.45] 400 (0-2.76) [0-27.60]
0-300 (0-2.07) [0-20.70] 75 (517) [5.17] 500 (3.45) [34.50]
0-400 (0-2.76) [0-27.60] 150 (1.03) [10.34] 500 (3.45) [34.50]
*These points will be used if switch trip point is not specified.
WRONG
UPMountingAngle
Wiring
CAUTION: DISCONNECT Electrical power before wiring.
1. Switch contacts (below) are shown
with no pressure applied to the
PSB switch.
2. A spade (forked) terminal
is recommended for all
PSB switch connections.
3. Complete the wiring operation
making sure the voltage and
current requirements are within
the PSB switch electrical
rating (see the typical wiring
diagram at right).
Normally
Closed (N.C.)
Normally
Open (N.O.)
Common (C)
PSB – –
To order the PSB model use the diagram below.
Pressure Range
Specify maximum value
from chart above.
Switch Trip Point .
F = Factory set to trip on falling. Specify “F” and the set point value.
Example: PSB-100-F20.
R = Factory set to trip on rising, Specify “R” and the set point value.
For units of measure other than psi, specify the set point value
followed by unit of measure as follows:
B = Bar
K = kPa/MPa
M = kg/cm2
Example: PSB-7B-2B
.Switch set point value will be stated on label.
How to Order
2-1/4 in.
(57 mm)
NO C NC
2-9/16 in.
(65 mm)
1/2 in. (13 mm)
Square wrench flats
1/8-27 NPT
2-1/32 in. Dia.
(52 mm)
Slot head terminal
screws (4-40, UNC-2A)
Dimensions Installation Instructions
Mounting
CAUTION: Use wrench on shank to tighten or loosen pressure
connection. DO NOT TWIST CASE, which will damage the unit and
void the warranty.
1. Before installing the PSB switch, apply sealant, such as Teflon tape,
to the threads (be sure sealant does not block the inlet orifice).
2. The PSB can be mounted in horizontal or vertical angles (do not
mount switch facing down).
3. Locate the unit in place and secure it by tightening
the 1/8-27 NPT fitting into the desired location (do not
overtighten). DO NOT TWIST CASE.
Trip Point Chart
Ranges available Factory setting* Maximum pressure
psi (kPa/MPa) [bar] psi (kPa) [bar] Falling psi (kPa) [bar]
0-15 (0-103) [0-1.03] 3 (21) [.21] 30 (207) [2.07]
0-30 (0-207) [0-2.07] 7 (48) [.48] 60 (414) [4.14]
0-50 (0-345) [0-3.45] 10 (69) [.69] 100 (0-689) [0-6.89]
0-75 (0-517) [0-5.17] 15 (103) [1.03] 150 (0-1.03) [0-10.34]
0-100 (0-689) [0-6.89] 20 (138) [1.38] 200 (0-1.38) [0-13.79]
0-150 (0-1.03) [0-10.34] 30 (207) [2.07] 300 (0-2.07) [0-20.70]
0-200 (0-1.38) [0-13.79] 50 (345) [3.45] 400 (0-2.76) [0-27.60]
0-300 (0-2.07) [0-20.70] 75 (517) [5.17] 500 (3.45) [34.50]
0-400 (0-2.76) [0-27.60] 150 (1.03) [10.34] 500 (3.45) [34.50]
*These points will be used if switch trip point is not specified.
WRONG
UPMountingAngle
Wiring
CAUTION: DISCONNECT Electrical power before wiring.
1. Switch contacts (below) are shown
with no pressure applied to the
PSB switch.
2. A spade (forked) terminal
is recommended for all
PSB switch connections.
3. Complete the wiring operation
making sure the voltage and
current requirements are within
the PSB switch electrical
rating (see the typical wiring
diagram at right).
Normally
Closed (N.C.)
Normally
Open (N.O.)
Common (C)
PSB – –
To order the PSB model use the diagram below.
Pressure Range
Specify maximum value
from chart above.
Switch Trip Point .
F = Factory set to trip on falling. Specify “F” and the set point value.
Example: PSB-100-F20.
R = Factory set to trip on rising, Specify “R” and the set point value.
For units of measure other than psi, specify the set point value
followed by unit of measure as follows:
B = Bar
K = kPa/MPa
M = kg/cm2
Example: PSB-7B-2B
.Switch set point value will be stated on label.
How to Order
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
specifications and designs at any time. MURPHY, the Murphy logo are registered and/or common lawwww.fwmurphy.com trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright
918.317.4100 Email: sales@fwmurphy.com protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.
Printed in U.S.A. 0591124M
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.