The Proflo Jr. monitors each cycle of a divider block system. If the pump deteriorates or if the lubricant flow slows down the cycle time, the Proflo? Jr. will shut down the compressor, preventing damage to cylinders, pistons, rods and packing.
Patented sealed magnet assembly. No lost magnets, springs or spacers EVER
Heavy duty magnet housing eliminated possibility of failure caused by bending
Proximity switch output is standard with every unit
Hall effect activated
Specificatons
3.3 volt hermetically sealed high temperature battery
AC or DC operation, switch rated for 300
VDC and 120 VAC @.5 amps
CPI No-Flow Safety Switch Proflo Jr 300VDC/120VAC Aluminum
CPI No-Flow Safety Switch Proflo Jr 6500400000PFJRT: Provides shut-down protection for your compressor based on the operation of the cycle times of the divider block system. If the pump deteriorates or if the lubricant flow slows down, the cycle time of the lube system will fall below the specified alarm time. This will prompt the Proflo Jr. to change to alarm state and shutdown the compressor, preventing damage to the compressor cylinders, pistons, rods and packing.
- 3.3 Volt hermetically sealed high temperature battery
- AC or DC operation, switch rated for 300VDC and 120VAC at 0.5 Amps
- Patented sealed magnet assembly, No lost magnets, springs or spacers EVER
- Heavy duty magnet housing eliminated possibility of failure caused by bending
- Proximity switch output is standard with every unit
- Hall effect activated
- Field replaceable battery
- For CPI HP/XD/DropsA/Trabon/SB/Lincoln divider block/valve applications
- Linking LED cycle indication
- Monitors movement of divider block piston for “timed” shutdown protection
- Closed loop or open loop operation
- Requires no external power
- Up to 10 year battery life, 5 year battery warranty
CPI No-Flow Safety Switch Proflo Jr 300VDC/120VAC Aluminum
CPI No-Flow Safety Switch Proflo Jr 6500400000PFJRT: Provides shut-down protection for your compressor based on the operation of the cycle times of the divider block system. If the pump deteriorates or if the lubricant flow slows down, the cycle time of the lube system will fall below the specified alarm time. This will prompt the Proflo Jr. to change to alarm state and shutdown the compressor, preventing damage to the compressor cylinders, pistons, rods and packing.
- 3.3 Volt hermetically sealed high temperature battery
- AC or DC operation, switch rated for 300VDC and 120VAC at 0.5 Amps
- Patented sealed magnet assembly, No lost magnets, springs or spacers EVER
- Heavy duty magnet housing eliminated possibility of failure caused by bending
- Proximity switch output is standard with every unit
- Hall effect activated
- Field replaceable battery
- For CPI HP/XD/DropsA/Trabon/SB/Lincoln divider block/valve applications
- Linking LED cycle indication
- Monitors movement of divider block piston for “timed” shutdown protection
- Closed loop or open loop operation
- Requires no external power
- Up to 10 year battery life, 5 year battery warranty